A. 800 MHz
B. 900 MHz
C. 1066 MHz
D. 1333 MHz
E. 1666 MHz
您可能感興趣的試卷
你可能感興趣的試題
A. Dual-rank DIMMs are not supported.
B. 16-GB DIMMs are too slow.
C. The largest DIMM an Intel 55xx or 56xx CPU can address is 32 GB
D. The memory bus would be too long.
E. The blade would run too hot.
A. Missing control VLAN in VSM configuration
B. Missing packet VLAN in VSM configuration
C. VSM has no network connection to vCenter
D. VSM extension key is not installed on vCenter
E. vCenter extension key is not installed on VSM
The network administrator is adding a new N1Kv to the vCenter, however, the administrator does not see the new switch under the networking tab of vCenter.
The administrator issues the following command on the VSM to troubleshoot:
VSM# show svs connections
connection VC:
ip address: 10.10.10.30
remote port: 80
protocol: vmware-vim https
certificatE. default
datacenter namE. DC1
DVS uuiD. 67 32 30 50 a6 d2 49 64-9e 1c 5f 49 e3 af 55 99
config status: Disabled
operational status: Disconnected sync status: -
version: -
When attempting to fix the issue, the following error is seen:
VSM-PRI-188# conf
VSM-PRI-188(config)# svs connection VC
VSM-PRI-188(config-svs-conn)# connect
ERROR: [VMWARE-VIM] Extension key was not registered before its use
What is the cause of the error?()
A. Missing control VLAN in VSM configuration
B. Missing packet VLAN in VSM configuration
C. VSM has no network connection to vCenter
D. VSM extension key is not installed on vCenter
E. vCenter extension key is not installed on VSM
Given the following configuration:
port-profile type ethernet DATA-UPLINK
vmware port-group
switchport trunk allowed vlan 1-3967,4048-4093
channel-group auto mode on
no shutdown
state enabled
port-profile type ethernet MGMT-UPLINK
vmware port-group
switchport trunk allowed vlan 10-12
channel-group auto mode on
no shutdown
state enabled
VEMs are seen to be joining and then are lost from the Cisco VSM. How would you resolve this issue?()
A. Remove second NIC from each port profile
B. Remove VEM from VSM (no vem X), remove NICs, and reinsert
C. Ensure that VLANs on uplink profiles are not overlapping
D. Reinstall VEM
E. Issue the command "module vem X execute vemcmd set pinning module vsm 1"
A. Send monitored traffic to a VLAN
B. Send monitored traffic to a remote VEM over L2
C. Receive monitored traffic on a vEthernet interface
D. Send monitored traffic to an IP destination
最新試題
KAL-AP on the Cisco ACE allows communication with Cisco ACE Global Site Selector, to report virtual IP and real server availability. Which statement is true about KAL-AP?()
Refer to the exhibit.The Cisco UCS domain is operating in switching mode. A network administrator notices that no traffic is traversing the uplinks on Fabric Interconnect B (Path C). Which actions might be used to change this behavior?()
Given the following output: san-port-channel 12 is up Hardware is Fibre Channel Port WWN is 24:0c:00:0d:ec:d3:5c:00 Admin port mode is NP, trunk mode is on Port mode is NP Port vsan is 1 Speed is 8 Gbps Member[1] : fc2/3 Member[2] : fc2/4 What does "Speed is 8 Gbps" indicate?()
What would be the cause for the following fault in UCS Manager?() "ether VIF x / xxx down, reason: ENM source pinning failed"
In the event of a GSS failure in a GSS cluster, which is true?()
Server load balancing (SLB) is the process of deciding to which server a load-balancing device should send a client request for service. Which predictors are supported on ACE in order to select the best server to fulfill a client request? ()
When testing ICMP access to a functional load-balancing ACE VIP, it fails. What is the reason of this problem? ()
Which are valid statements about Cisco Virtual Interface Card (VIC)? ()
Which statement is true about "full state backup" in a Cisco Unified Computing System?()
In a Cisco Unified Computing System, What is the "designated receiver" port in end-host mode used for?()