A.wax precipitation in the lube oil
B.contamination by dust, scale, or moisture
C.refrigerant bubbles in the lube oil
D.refrigerant reducing the lube oil viscosity
您可能感興趣的試卷
你可能感興趣的試題
A.increasing refrigerant pressure in the coil
B.increasing chilled water flow through the cooler
C.sub-cooling the refrigerant in the condenser
D.superheating the refrigerant in the compressor
A.control inlet air temperature
B.control inlet air volume
C.maintain relative humidity at 15%
D.restore conditioned air temperature to a comfortable level
A.bilge well connected to that valve, plus the second bilge well being pumped will be completely emptied
B.bilge system will lose vacuum and prevent the other bilges from being pumped out
C.bilge well aft connected to that valve will siphon its contents to the forward bilge wells
D.discharge pressure will be too high
A.bypass exhaust gas at high loads to prevent excessive back pressure
B.bypass a portion of the exhaust gas at peak loads for better efficiency
C.recycle exhaust gas to the turbocharger
D.minimize moisture condensation in the boiler gas passages at low loads
A.Correct the cause of the scoring and repair the sleeve or replace with a new one
B.Reassemble the unit and provide more water leak off for proper lubrication
C.Check for parallel alignment of the sleeve radial faces to the sleeve bores
D.Reassemble the unit and adjust the governor to obtain a slower speed
最新試題
Engine parameters shall be corresponded to NOx Technical Files. This is required by ()
Under MARPOL Code the ship to which it applies has to carry ()
A purge recovery system is used in a centrifugal air conditioning or refrigeration system to ()
The flash point of a residual fuel oil should be used to determine the highest temperature to which oil may be heated()
By comparing the exhaust gas temperature of each cylinder, the operator can determine if the load is balanced throughout the engine. The device most commonly used is a()
()connectors hold best if a wire is accidentally pulled or a connection becomes loose.
If separating effect is not good, which measure should be taken ()
The additional mark ()in the Classification Certificate for Machinery means propulsion apparatus is remotely controlled on the navigating bridge control station, and engine assembly control station is unmanned periodically.
One of the reasons that cause oil flowed from sludge outlet of a self-cleaning separator is()
“Insufficiency of manning or insufficiency of certification of seafarers” is an identification of a()